Uploaded image for project: 'Service Orchestrator'
  1. Service Orchestrator
  2. SO-3677

Fail creating multiple VNF/VF-Module of same model using MACRO

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Highest Highest
    • Istanbul Release
    • Istanbul Release, Guilin Maintenance Release 1, Honolulu Maintenance Release 1

      Current logic for Macro flows in SO prevents users from creating mutliple vnfs or vf-modules of the same model. During creation, modelCustomizationId is being used to differentiate which resource should be created. In a payload with multiple resources (vnf or vf-module) having the same modelCustomizationId, the first one will always be returned. This causes building blocks to be skipped and resources will not be created.

       

       