      As VID SE, I want VID to allow a user to navigate from the instantiation status page directly to the drawing board after a pause situation. A Pause condition (either success or failure) needs to have happened in order to allow the user to resume to the next vfmodule creation.

       

      Resume button: This function will allow the user to resume a successfully paused vfmodule to continue with the flow by sending request to MSO to resume with instantiation.  

       

       

      VID shall also have a redeploy capability which will allow for the failed vfmodule to continue. The instantiation status page will have a redeploy link/function that will navigate the user to the drawing board. From the drawing board user shall have a edit button as well as redeploy button.  Please see the behavior for each capability below:

       

      Edit button:  This function will allow the user to edit all the vfmodules that  are not successfully completed or not in-progress. But users are allowed to edit all the vfmodules which the instantiations has not started or instantiation failed that are on drawing board. User are not allowed to add or removed vfmodules.

       

      Redeploy button: This function will allow the user to resume a vfmodule which is paused successfully without any error, once user click on resume, VID shall send another instantiation request to MSO to retry the last failed task.

       

      Acceptance Criteria:

      • Verify from VID’s instantiation status page, VID has redeploy link/function for failed vfmodules which would navigate the user to drawing board.
      • Verify from VID’s instantiation status page, VID has resume capability for successfully paused vfmodules which would navigate the user to drawing board.
      • Verify user have the “Edit” button on VID’s drawing page so that they can edit all the vfmodules that have failed status or instantiation has not started.
      • Verify user are not allowed to edit completed vfmodule or in-progress vfmodule on VID’s drawing page.
      • Verify user have redeploy capability for all the vfmodules that are in failed state from VID’s drawing page. VID shall send request to MSO to re-instantiate the failed vfmodule once user invokes Redeploy.