Uploaded image for project: 'Clamp'
  1. Clamp
  2. CLAMP-807

Undeploy operation cannot be refreshed successfully

    XMLWordPrintable

Details

    • Bug
    • Status: Closed
    • Low
    • Resolution: Done
    • Frankfurt Release
    • Frankfurt Release
    • None
    • CLAMP-R6 Sprint 5

    Description

      The undeploy operation is executed properly by DCAE but it failed to be refreshed properly by CLAMP.

      Comment from Vijay:
      Vijay(12:07:34 AM): i can see query on Deployment handler for get which is failing bcoz the execution id is not longer valid in DCAE
       
      Possibly Clamp does query DCAE but it can't answer anymore because this is not valid,
      may be the workflow 'UNdeploy" should be revisited
       

      Workaround:

      Re-open the Loop again and the DCAE undeploy should be fine

      Attachments

        Issue Links

          No reviews matched the request. Check your Options in the drop-down menu of this sections header.

          Activity

            People

              xuegao Xue Gao
              sebdet Sébastien Determe
              Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: