Uploaded image for project: 'Network Controller'
  1. Network Controller
  2. SDNC-1430

SDNC restart needed every 24-36h during stability test

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Medium Medium
    • Guilin Release
    • None

      During stability test, we trun the basic_vm continuously (when it finishes, we restart it)

      During a 7 days tests, it was needed to restart the SDNC to recover the PASS state of the test.

      We can see in the graph that the memory is increasing and when reaching a threshold, the test does not work anymore

       

      it is documented in the test stability page

      Note a simple restart of the SDNC fixes the issue.

      The limits in OOM are set to 4 GiB

      the requests to 2 GiB

      even the limit is lower that the consumption recorded by prometheus. The request/limits are probably too low.

       

            djtimoney Dan Timoney
            mrichomme mrichomme
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

              Created:
              Updated:
              Resolved: