Uploaded image for project: 'Service Orchestrator'
  1. Service Orchestrator
  2. SO-2779

A deadlock occured while execute sdncAdapter Callback message correlation.

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Medium Medium
    • None
    • Dublin Release
    • None

      During concurrent testing,we found that there was a deadlock problem in sdncAdapter Callback message correlation.

      So, Execution of sdncAdapter in concurrent process will lead to database deadlock.
       
      I find this is a known problem on camunda jira.Their number is  cam-6468 and cam-3318.
       
      The attachment is the error log during the test.

       

      2020-05-09

      I have tested this problem with the Frankfurt version. Do you have a solution?

       

       

        1. 111.diff
          0.8 kB
        2. deadlock.PNG
          deadlock.PNG
          108 kB
        3. deadlock2.PNG
          deadlock2.PNG
          130 kB
        4. JDBC异常.PNG
          JDBC异常.PNG
          144 kB
        5. 捕获.PNG
          捕获.PNG
          136 kB

            seshukm seshukm
            xichunguang xichunguang
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

              Created:
              Updated:
              Resolved: